Premier Laboratory Partner for a Better World Analytical scientists and clinical researchers worldwide rely on Agilent to help fulfill their most complex lab. We would like to show you a description here but the site won’t allow us. Help File - User Manual for E5071C ENA Network Analyzer (Operation and Programming) The E5071C help system provides easy access to information related to the use of E5071C ENA Network Analyzer. The E5071C help includes the information of Quick Start, Specification, Operation and Programming. If you need a manual: ALL available manuals (Agilent, Keysight & HP) for discontinued and obsolete products are provided online. Use the search box on the upper part of this page and enter your model number. If a manual exists, you will find that manual in the Document Library tab for the product. : Agilent-Technologies Agilent-Technologies-G3180B-Users-Manual-413162 agilent-technologies-g3180b-users-manual-413162 agilent-technologies pdf.
Advertising
ESG Family Signal Generators
Equipment Required
Required Equipment
Calibration Guide
1-3
• HP/Agilent 8904A Function
Generator
1
Frequency range (sinewave):
0 Hz to 600 kHz
0 Hz to 600 kHz
AC Amplitude (sinewave only):
Range: 0 to 10 Vp-p into a 50
Ω
load
Flatness (>630 mVp-p into 50
Ω
):
±
0.1% (
±
0.009 dB), 0.1 Hz to 100 kHz
• HP/Agilent 53132A Option 050
Universal Counter
1
Frequency range: 4 GHz
Resolution: 0.1 Hz
![Agilent Agilent](/uploads/1/2/5/0/125056908/860731801.jpg)
External timebase input
• HP/Agilent 33120A Option 001
Arbitrary Waveform Generator
1
(2)
(No Substitution)
• HP/Agilent 438A Power Meter
1
Instrumentation accuracy:
±
0.5%
Power reference accuracy: 0.9%
• HP/Agilent 8482A Power Sensor
Frequency range: 100 kHz to 4000 MHz
Power range:
−
30 dBm to +13 dBm
Maximum SWR:
100 kHz to 300 kHz: 1:1.6,
300 kHz to 1 MHz: 1:1.12,
1 MHz to 2 GHz: 1:1.1,
2 GHz to 4 GHz: 1:1.3
100 kHz to 300 kHz: 1:1.6,
300 kHz to 1 MHz: 1:1.12,
1 MHz to 2 GHz: 1:1.1,
2 GHz to 4 GHz: 1:1.3
Calibration factor accuracy (RSS):
≤
1.6%
• HP/Agilent E3615A Power Supply
Minimum Power: 15V
Minimum Current: 325 mA
• MD/MDC-174 Mixer
Frequency range: 0.001 to 2.8 GHz
User Manual Template
• MD/MDC-164 Mixer
Frequency range: 0.5 to 9 GHz
• HP/Agilent 3458A Digital
Multimeter
1
dc Volts: 0.1 to 100 V
Input resistance: 10
Ω
to 1 K
Ω
• HP/Agilent 8491A/B Option 006
Attenuator
Attenuation: 6 dB
• HP/Agilent 8491A/B Option 010
Attenuator
Attenuation: 10 dB
• HP/Agilent 8491A/B Option 020
Attenuator
Attenuation: 20 dB
• Personal Computer (included in
HP/Agilent E5500A/B)
Running MS Windows® 3.1/95/98 or
Windows NT®
Windows NT®
• HP LaserJet 5L Printer
MS Windows supported
• HP 82341C GPIB Interface Card
with SICL HP I/O Library Installed
(No Substitution)
(No Substitution)
• Agilent Technologies E4400-60073
Digital Test Card (No Substitution)
• HP/Agilent 8495G Programmable
Step Attenuator
Attenuation: 0 to 70 dB
Frequency range: dc to 4 GHz
• HP/Agilent 11713A Step Attenuator
Driver
• HP/Agilent E5500A/B Phase Noise
Measurement System
2, 3
Frequency range: 0 to 4 GHz
1.
Equipped with GPIB
2.
Includes Personal Computer
3.
Agilent N3300a User Manual
![User manual pdf User manual pdf](/uploads/1/2/5/0/125056908/257538072.jpg)
Required for ESG-AP/DP only
Advertising
Table of contents- Title Page
- Table of Contents
- 1 Equipment Required
- Required Equipment
- 2 Operation Verification
- Verification Procedures
- 3 Service Software
- ESG Family Support Software Administration
- Running the Service Support Software
- 4 Performance0011Tests
- Support Software
- 1. Internal FM Accuracy and Distortion
- 2. Internal AM Accuracy and Distortion
- 3. Phase Modulation Accuracy and Distortion
- 4. FM Frequency Response
- 5. AM Frequency Response
- 6. Phase Modulation Frequency Response
- 7. DCFM Frequency Offset Relative to CW
- 8. Residual FM (ESG-A and ESG-D only)
- 9. Harmonic, Subharmonic, and Nonharmonic0011Spurious0011Signals
- 10. Power Level Accuracy
- 11. Timebase Aging Rate
- 12. Digital Modulation Level Accuracy
- 13. Internal Digital Modulation Quality
- 14. Custom I/Q RF Modulation Quality (Option0011UN80011only)
- 15. I/Q Modulation Quality (Options UN3, UN4 & UN8)
- 16. Pulse Modulation On/Off Ratio
- 17. Burst Modulation On/Off Ratio (ESG-D only)
- 18. CDMA Adjacent Channel Power (Option UN5 only)
- 19. Alternate Timeslot Power Settling Time (Option0011UNA0011only)
- 20. Pulse Rise/Fall Time (Option 1E6 only)
- 21. Measuring Phase Noise and Residual FM (ESG-AP0011and0011ESG-DP0011Series0011Signal0011Generators)
- 22. Dual Arbitrary Waveform Generator Check (Option0011UND0011only)
- 23. GSM Loopback BER Check (Option 300 only)
- 24. Frac-N Check (ESG-AP,0011ESG-DP0011only)
- 25. Sampler/YO Driver Check (ESG-AP,0011ESG-DP0011only)
- 5 Adjustments
- Adjustment Relationships
- Internal Reference Oscillator Adjustment
- Analog Bus ADC Calibration
- Pretune Calibration
- Internal Source Calibration
- VCO Bias Potentiometer Adjustment
- Lock Angle Potentiometer Adjustment
- KV versus Frequency Calibration
- AM Audio Path Offset Calibration
- Timebase DAC Calibration
- FM Scale DAC Offset Calibration
- FM Path Offset Calibration
- FM In-Band DAC Offset Calibration
- FM Inverting Amplifier Offset Calibration
- FM 1/2 Path Ratio Gain Calibration
- Modulation Source Relative0011Gain0011Compression0011Calibration
- FM Out-of-Band Calibration (ESG-A0011and0011ESG-D0011only)
- FM Delay Potentiometer Adjustment
- Wide Bandwidth Phase Modulation Calibration
- FM/PM Out-of-Band Calibration
- FM/PM YO Frequency Compensation Calibration
- DCFM Calibration
- Low Frequency (LF) Output Calibration
- External Input Peak Detector Calibration
- Burst Modulator Calibration
- Burst Audio Path Gain Calibration
- Prelevel Calibration
- Prelevel Calibration, Analog (ESG-A0011only
- Gain Adjust Calibration
- Low Noise Floor Gain Adjust
- ALC Modulation Driver Bias Calibration
- VBLO Mixer Bias Calibration
- Power Level Accuracy
- Level Meter Calibration
- ALC Modulation Flatness Calibration
- AM Gain Calibration
- I/Q Gain/Offset/Quadrature Calibration
- I/Q Impairment Adjustment
- Baseband Generator I/Q Gain and Offset Adjustment
- 6 Maintenance and Service
- Preventive Maintenance Procedures
- 7 Safety and Regulatory
- Electrostatic Discharge
Popular Brands
Agilent E4407b User Manual
Popular manuals